DA-710 Series HW User’s Manual Hardware Installation
Power Input Wiring Description
Refer to the following section for detailed power input wiring descriptions.
Terminal
Number
Description Note
1 PWR1 Line/ DC +
PWR1 Line / DC + is connected to the positive (+) terminal
if the power source is DC and to the Line terminal if the
power source is AC.
2 PWR1 Neutral / DC -
PWR1 Neutral / DC - is connected to the negative (-)
terminal if the power source is DC and to the Neutral
terminal if the power source is AC.
3 PWR1 Surge Ground
PWR1 Surge Ground is connected to the Chassis Ground
terminal via a jumper on the terminal block. Surge Ground
is used as the ground conductor for all surge and transient
suppression circuitry. NOTE: Surge Ground must be
disconnected from Chassis Ground during HIPOT
(dielectric strength) testing.
4 Chassis Ground
Chassis Ground is connected to the Safety Ground terminal
for AC inputs or the equipment ground bus for DC inputs.
Chassis ground connects to both power supply surge grounds
via a removable jumper.
5 NC
No function
6 NC
No function
7 Chassis Ground
Chassis Ground is connected to the Safety Ground terminal
for AC inputs or the equipment ground bus for DC inputs.
Chassis ground connects to both power supply surge grounds
via a removable jumper.
8 PWR2 Surge Ground
PWR2 Surge Ground is connected to the Chassis Ground
terminal via a jumper on the terminal block. Surge Ground is
used as the ground conductor for all surge and transient
suppression circuitry. NOTE: Surge Ground must be
disconnected from Chassis Ground during HIPOT
2-8