Software Installation
Intellio C320Turbo User's Manual 3-27
The board reset utility eliminates the need to shut down the UNIX system to re-
initialize the Intellio C320Turbo board with new configuration. Press Enter to start
board reset.
However, before the board reset is issued, user must make sure that
1. All enabled ports must be disabled.
2. All processes related to the Intellio C320Turbo, including getty or tty monitor, are
killed.
After board reset, the following message may show if it is successful.
MOXA Serial I/O Board (Ver x.x)
Downloading
MOXA-C320Turbo (MemBank=XX000) is found.
If one of the following messages appears, please see Chapter Troubleshooting.
WARNING! C320Turbo (MemBank=XX000) not found!
or
ERROR! C320Turbo (MemBank=XX000) download failed!
Vue de la page 52