Moxa Technologies INTELLIO C218 Manuel d'utilisateur Page 42

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 100
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 41
3-24 Intellio C218Turbo User's Manual
Baud Rate Mapping
This advanced feature is set to “High Bandby default, indicating that the baud
rate 50, B50, will no longer stand for 50 bps. Instead, B50 means 57600 bps,
B75 is for 115.2 Kbps, B110 is for 230.4 Kbps, and B134 is for 460.8 Kbps, and
B150 is for 921.6 Kbps. You may press F1 Help for on-line details.
If this feature is set to “Low Band”, the original definition of UNIX baud rate
mapping are used.
2. Press PageDown to enter “Advanced Port Settings” sub-dialog, there are some
noticeable fields for initialize the port for advanced usage. You may skip this step