Wiring the Power Inputs
The two left-most contacts of the 3-contact terminal block connector on the
EDS’s top panel are used for the DC and AC inputs. Top and front views of
one of the terminal block connectors are shown here.
STEP 1: Insert the negative/positive DC wires
into the V-/V+ terminals.
STEP 2: To keep the DC wires from pulling
loose, use a small flat-
b
lade screwdriver to tighten
the wire-clamp screws on the front of the terminal
block connector.
STEP 3: Insert the plastic terminal block
connector prongs into the terminal block receptor,
which is located on the EDS’s top panel.
y Only connect to a class 2 power supply.
y Only use 60/75°C copper (CU) wire, 28-12 AWG.
y Use a maximum torque of 4.5 in-lb.