Vue de la page 52
Software Installation
Intellio C218Turbo /PCI User's Manual 3-35
Checking Board Initialization Status
When the system starts up and enters into the multiuser mode, you should see the
board initialization status report, which is same as one of the messages described in
the “Board Reset” part of previous section.
Setting MOXA Ports to Terminal
Following procedure is how to set the MOXA port to the “Terminal” for login
purpose, taking ttya11 as an example,
SCO UNIX/OpenServer/Open Desktop/XENIX
# enable /dev/ttya11
UNIX SVR4.2 and UnixWare
1. Edit (e.g. use vi editor) the file /etc/inittab.
2. Modify the tty entry from "ma11:23:off:/etc/getty ttya11 9600" to
"ma11:23:respawn:/etc/getty ttya11 9600".
3. # init q
Or refer to your UNIX system manuals for how to activate a tty port.
Vue de la page 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 92 93

Commentaires sur ces manuels

Pas de commentaire