NPort IA5150/5250 Series User’s Manual Web Console Configuration
5-22
Connection control
Setting Factory Default Necessity
Startup/None,
Any Character/None,
Any Character/Inactivity Time,
DSR ON/DSR OFF,
DSR ON/None,
DCD ON/DCD OFF,
DCD ON/None
Startup/None Required
The meaning of each of the above settings is given in the table below. In general, both the Connect
condition and Disconnect condition are given.
Connect/Disconnect Description
Startup/None
(default)
A TCP connection will be established on startup, and will remain
active indefinitely.
Any Character/None
A TCP connection will be established when any character is received
from the serial interface, and will remain active indefinitely.
Any Character/
Inactivity Time
A TCP connection will be established when any character is received
from the serial interface, and will be disconnected when the Inactivity
time out is reached.
DSR On/DSR Off
A TCP connection will be established when a DSR “On” signal is
received, and will be disconnected when a DSR “Off” signal is
received.
DSR On/None
A TCP connection will be established when a DSR “On” signal is
received, and will remain active indefinitely.
DCD On/DCD Off
A TCP connection will be established when a DCD “On” signal is
received, and will be disconnected when a DCD “Off” signal is
received.
DCD On/None
A TCP connection will be established when a DCD “On” signal is
received, and will remain active indefinitely.